Brand Name : Macylab

Model Number : AA-1800DL

Certification : CE,FCC,FDA,ROHS,9001

Place of Origin : China

MOQ : 1pcs

Price : USD11000--USD 16000

Payment Terms : T/T, L/C, Western Union, MoneyGram

Supply Ability : 5000set/M

Delivery Time : within 7 days

Packaging Details : Carton

Model : AA-1800DL

Power Supply : 110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current : pulsed power supply

Optical System : Large 1800 /mm grating ruling, full closed optical system

Wavelength Range : 185nm-900nm Automatically peak find,a key opticaloptimization function

Wavelength Accuracy : ±0.15nm

Wavelength Repeatability : <0.10nm

Spectral Bandwidth : 0.1、0.2、0.4、0.7、1.0、1.4、2.0nm (7 steps with automatic changeover)

Baseline Stability : ≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

Absorbance Range : 0-4A

Detector : imported photomultiplier tube

Burner Head : full titanium combustion head, 50mm or 100mm generalcombustion head

Atomization Chamber : polymer explosion-proof spray chamber

Nebulizer : atomizer efficient glass atomizer, can also be customized

Ignition Type : Microcomputer control, automatic ignition

Gas Control : automatic gas control system

Detection Limits(Cu) : 0.002μg/mL

Precision : RSD≤0.5%

Contact Now

AA-1800DL Atomic Absorption Spectrophotometer

AA-1800DL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

AA-1800DL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

Main features

High precision automatic optical system

1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be

respectively preheating

Polymer spray chamber

Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

Titanium burner

Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

Automatic analysis

It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic

adjustment of the power supply parameters and the beam

position, automaticwavelength scanning and searching peak

Software function

High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

Technical parameters

Mainframe
Model : AA-1800DL
Light Source : ≤8 lamps automatic turret, automatic alignment
Power Supply : 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current : pulsed power supply
Optical System : large 1800 /mm grating ruling, full closed optical system
Wavelength Range : 185nm-900nm
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy : ±0.15nm
Wavelength Repeatability : <0.10nm
Spectral Bandwidth : 0.1,0.2,0.4,0.7,1.0,1.4,2.0nm
(7 steps with automatic changeover)
Baseline Stability : ≤±0.002A/30 min (Static)
≤±0.004A/30min (Dynamic)
Absorbance Range : 0-4A
Flame Analytical System
Detector : imported photomultiplier tube
Burner Head : full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber : polymer explosion-proof spray chamber
Nebulizer : atomizer efficient glass atomizer, can also be customized
Ignition Type : microcomputer control, automatic ignition
Gas Control : automatic gas control system
Detection Limits(Cu) : 0.002μg/mL
Precision : RSD≤0.5%

Eight Lamp Method Flame Atomic Absorption Spectrometry CEEight Lamp Method Flame Atomic Absorption Spectrometry CEEight Lamp Method Flame Atomic Absorption Spectrometry CE


Product Tags:

ce flame atomic absorption spectrometry

      

eight lamp flame atomic absorption spectrometry

      

eight lamp method faas spectrometry

      
 Eight Lamp Method Flame Atomic Absorption Spectrometry CE Manufactures

Eight Lamp Method Flame Atomic Absorption Spectrometry CE Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Macylab Instruments Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)