195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

Macylab Instruments Inc.
Contact Now

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

  • 1
  • 2

Brand Name : Macylab

Model Number : ICP-6800

Certification : CE ISO ROHS FCC FAD

Place of Origin : China

MOQ : 1pcs

Price : USD33900/Set

Payment Terms : Western Union, MoneyGram, T/T, L/C

Supply Ability : 5000Set / year

Delivery Time : 20-300days

Packaging Details : Wood Box

Product Name : Inductively Coupled Plasma Optical Emission Spectrometer

key words : single channel

Optical Structure : Czerny-Turner

Frequency : 27.12MHz±0.05%

Repeatibility : RSD<=1.5%

Stability : RSD <=2%

Output power : 800W-1200W

Dimensions : 125x69.3x64.5cm

Scanning Wavelength Range : 195nm-500nm(3600L/mm grating), 195mm-500nm(2400L/mm grating)

Photomultiplier Specification : R293 or R298

Contact Now

Inductively Coupled Plasma Optical Emission Spectrometer ICP-6800

Main features

Performance stability:The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

Injection automation:Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

Precision analysis:The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.

Quick test:In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis


Technical parameters

RFPower technical parameter

Circuit type :solid-state RF Power supply, with function of automatch

Frequercy :27.12MHz±0.05%

Frequency Stablity :<0.1%

Power Output :800W-1500W

Power Output Stability :<0.3%

Escaped RF radiation :30cm away from the instrument, electric fiekd: E<2Vtm

Sampling System Technical Parameter

Output working coil imer diameter :25mm

Torpue tube:Three concentric, extemal diameter 20mm

Coaxial nebulizer :Outer dameter 6mm

Double barrel atomizing chamber:Outer diameter 34mm

Gas Flow Controls

Plasma Argon Flowmeter :(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter :(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter :(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value :(0-0.4MPa)

Cooling Water:Temperature :20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa


Certificate 195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

Spectrometer

Optics Czerny-Turner type

Focal length 1000 mm

Grating Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion 0.26nm/mm

Resolution ≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range 3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor ≤0.0006 nm

Exit Slit 12μm

Entrance Slit 10μm

Photoelectric Converter Performance

Photomultiplier tube specification :R293/R928

Negative HV on PMT 0-1000V

Stability <0.05%

Overall Performance Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Exhibition:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

Our Company:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

The Factory:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel


Product Tags:

195nm czerny turner spectrometer

      

single channel czerny turner spectrometer

      
 195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel Manufactures

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel Images