Brand Name : macylab

Model Number : UV-1900PC

Certification : all

Place of Origin : China

MOQ : 1

Price : USD /SET

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 50SET/day

Delivery Time : within 5 days

Packaging Details : PE FILEM THEN PUT INTO CARTON

Optical System : Double beam

Wavelength Range : 190-1100nm

Band Width : 0.1、0.2、0.5nm、1.0、2.0、4nm

Wavelength Accuracy : ±0.3nm

Wavelength Repeatability : ≤0.1nm

Photometric Accuracy : ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)

Photometric Repeatability : 0.1% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)

Stray Light : ≤0.008% τ (220nm NaI,340nm NaNO2)

Stability : 0.0005A/h@500nm

Noise : ± 0.0002A @500nm

Baseline Flatness : ± 0.001A

Photometric Mode : T,A,C,E

Wavelength Setting : Automatic

Display Mode : 6 inches high brightness blue LCD

Detector : Import Silicon Photodiode

Light Source : Import Deuterium Lamp & Tungsten Halogen Lamp

Power Requirement : AC 220V/50Hz 110V/60Hz

Power : 120W

Dimensions(W*D*H) : 560×450×230mm

Weight : 28Kg

Contact Now

Dual-beam UV-Vis spectrophotometer

Model:UV-1900
Dowload:Download the attachment immediately
Consultation: Consultation
Contact: Contact

Product description, technical parameters and configuration

Character

●UV-1900 dual-beam optical system, successfully achieved the perfect combination of high accuracy and reliability measurement to meet the requirements of various applications that can be used in biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical testing, health and epidemic prevention, and other fields.

●A wide wavelength range, the wavelength range to meet the various requirements of the field

●4nm, 2nm, 1nm, 0.5nm, 0.2nm, 0.1nm spectral bandwidth of the six countries to meet the stringent requirements of different users and pharmacopoeia

●Automatic design to achieve the most simple means of measurement

●LSI design greatly improves the scalability and reliability of the system

●Improved optimization of the optical design, import source and receiver system created a high performance and high reliability

●Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three- wavelength (optional) DNA protein measurements (optional), and other measurement methods to meet different measurement requirements, and can be displayed directly on a 6-inch screen

●Based on user requirements optional hole rack, manual four with stand, manual Eighth rack, automatic Eighth frame, glass stand, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks

●Measurement data can be output through the printer with USB interface

●Can be powered down to save the measurement parameters and data, user-friendly

●Can achieve more accurate and flexible measurement via PC control, which can meet the needs of different users

Technical Specifications
Optical System
Double beam
Wavelength Range
190~1100nm
Band Width
0.1,0.2,0.5nm,1.0,2.0,4nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.1nm
Photometric Accuracy
±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability
0.1% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light
≤0.008% τ (220nm NaI,340nm NaNO2)
Stability
0.0005A/h@500nm
Noise
± 0.0002A @500nm
Baseline Flatness
± 0.001A
Photometric Mode
T,A,C,E
Wavelength Setting
Automatic
Photometric Display Range
-4~4A
Display Mode
6 inches high brightness blue LCD
Detector
Import Silicon Photodiode
Light Source
Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement
AC 220V/50Hz 110V/60Hz
Power
120W
Dimensions(W*D*H)
560×450×230mm
Weight
28Kg

Double Beam wavelength range and 5 spectral bandwidths Ultraviolet Visible spectrophotometer

Double Beam wavelength range and 5 spectral bandwidths Ultraviolet Visible spectrophotometer

Double Beam wavelength range and 5 spectral bandwidths Ultraviolet Visible spectrophotometer


Product Tags:

uv-1900pc laboratory spectrophotometer

      

120w laboratory spectrophotometer

      

laboratory uv spectrophotometer double beam

      
 Double Beam wavelength range and 5 spectral bandwidths Ultraviolet Visible spectrophotometer Manufactures

Double Beam wavelength range and 5 spectral bandwidths Ultraviolet Visible spectrophotometer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Macylab Instruments Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)